Home    PHOTOCONTROL    3 wires MINI PHOTOCONTROL AA2405E

3 wires MINI PHOTOCONTROL AA2405E

Contact Us>
AA2410E uses industrial-grade low-power operational amplifiers and relay output circuits. Despite being powered by an RC voltage drop method, its own power consumption remains very low during cross-voltage operation. The delay-on and delay-off light functions effectively prevent the impact of short-term interference light, extending the service life of lamps and switches. It is widely used in automatic control of LED lights.

Technical Data

Rated V.

120/208/220/240/277Vac  50/60Hz

Rated  Load

9.8A@120V,8A@208/240V,2.4A@277V

power dissipation

< 0.8@120V avg

Turn-on  Levels

<25Lux

Turn-off Levels 

<65Lux or Requirement

Time Delay  

<30S

IP

Housing :IP54, IP65; Borrow light: IP67 

Switch Times

> 5000 Times

Light Sensor

∅5MM CDS or Silicon Photoresistor

Cover Material

PC  UV

Cap Material

PC  UL94-V2  F1 UV resistant 

Power Wire

BVR1 C C C or 18AWG  UL1015

Ambient Temp.

-30~70℃

Insulation

3000V 60Hz  60s

Certificate

CE UL 

Warranty

3years

Boundary dimension

51x26x24.5

 

Installation

 

installed by an electrician.

●Maintenance and replacement installation: Turn off the power, fold off the bad photocell, replace a new photocell and connect the wire and do a good job of insulation. Note that the top of the photocell must point to the ground.

●New installation: First of all, install the optical controller correctly according to the requirements, and then connect the wiring correctly according to the wiring diagram, and then power on after confirming the connection.

●TEST

After confirming that the connection is correct, turn on the power and the photocell will light up for about 1s and then turn off first. If it is during the day, use a black bag to cover the photocell, the light will turn on after 30s, remove the bag light will turn off after 30s.